Matrix SETU ATA211G System Manual 39
2. You can assign a Name to the Mobile port, which will be displayed to the called party (if the instrument of
the called party supports display name functionality).
The name you assign may consist of a maximum of 24 characters. Default: Blank.
Incoming Call
1. Select an appropriate Incoming Call Routing option for the Mobile Port. You may select:
• Reject Incoming Calls: Select this option if you want ATA211G to reject the incoming calls on the Mobile
port.
• Route to FXS: Select this option if you want to route the incoming calls on Mobile port, to the FXS port.
The incoming call will be placed on the FXS Port and the phone connected to the FXS Port will start ringing
for the duration of the Ring Timer (default: 45 seconds). If the call is not answered within this timer, it will
be rejected. This is also the default option.
If you select this option, you may configure the Ring Timer. Valid range of this timer is 01-99 seconds.
• Route to fixed destination number as per incoming call route selection: Select this option if you want
incoming calls on the Mobile Port to be routed to a Fixed Destination Number as per the Incoming Call
Route you select: SIP1, SIP2, SIP3 or Dialed Number Table.
If you select this option, define the destination number in the Fixed Destination Number field and select
the Incoming Call Route.
• Route to FXS. If not answered within ring timer, route to fixed destination number as per incoming
call route selection: Select this option if you want to route the incoming calls on the Mobile Port to the
FXS Port first. The phone connected to the FXS Port will start ringing for the duration of the Ring Timer
(default: 45 seconds). If the call is not answered within this timer, the call will be automatically routed to the
Fixed Destination Number as per the Incoming Call Route you select: SIP1, SIP2, SIP3 or Dialed Number
Table.
If you select this option, define the destination number in the Fixed Destination Number field and select
the Incoming Call Route.