Matrix Vision Spezifikationen Seite 52

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 235
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 51
Matrix
52
Vision System Manual
Example 2:
Program station 22 (software port number 01) for following constraints:
Disconnect all calls starting with ‘0’ after 240 seconds except calls starting with ‘022’.
Solution:
As observed this type of requirement cannot be met by any of the default CDC tables. Hence, customize CDC
Table 1 and assign it to station 22.
Program the number ‘0’ in denied list 7 and ‘022’ in allowed list 7. (This step is necessary because default
allowed and denied lists does not contain such as option whereby 022 is available in allowed list and 0 is
available in denied list).
1202-1-7-00-022-#*
1203-1-7-00-0-#*
Assign this allowed list to CDC table 1.
4915-1-1-7
Assign this denied list to CDC table 1.
4916-1-1-7
Assign CDC Timer of 220 seconds (not 240 seconds because 20 seconds are added to CDC Timer for
actual disconnection).
4914-1-1-220
Other parameters are already available by default hence no need to reprogram them.
Assign CDC table 1 to station 22.
4920-1-01-1
Important Point:
It is possible to disconnect specific outgoing calls. For example it is possible to disconnect all calls to
022-28765432 after 180 seconds.
Relevant Topic:
1.
Allowed and Denied Lists 31
=X=X=
Seitenansicht 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 234 235

Kommentare zu diesen Handbüchern

Keine Kommentare