Matrix Installation and Operation Instructions
11.2 Types of Installation
There are two basic methods of installing the ventilator in the Matrix:
Exhaust at the source. Stale air is drawn from the kitchen and bathrooms.
Exhaust from the return (Simplified System). Stale air is drawn from the return plenum.
6’-0” min
Cold Air
Return
Stale Air From
Kitchen and
Bathroom
External Ducting to be 6”
insulated with Vapor Barrier
18” min
Warm Air
Supply
6’-0” min
Cold Air
Return
Stale Air From
Cold Air Return
(Connection to be 4ft from
where return plenum attaches
to Matrix)
External Ducting to be 6”
insulated with Vapor Barrie
r
18” min
Warm Air
Suppl
y